September 09th, 2013

9/9/2013

Comments

 
Picture

We’ll be at the 2013 World Molecular Imaging Congress in Savannah, Georgia this month.  If you are at the conference, be sure to drop by booth 312 to see our latest offerings.


This is our first time as an exhibitor at WMIC, and we look forward to meeting new people and old friends, as well as having many interesting discussions.

There will be a CT Sabre on display, going through its motions.  If you want a sneak preview, you can see a recorded version of what the demonstration will be like on the Parallax Channel.
Picture
Also, one of the featured sessions at this year's conference is "The Relationship Between Radiology and Molecular Imaging".  We've had some experience with adding radiation therapy capabilities to micro-CT scanners.  So, if this is an area of interest for you, please stop by to chat after the session. 
Comments

CT Sabre

12/10/2012

Comments

 
Picture
Parallax Innovations is pleased to preview another cutting-edge product – the CT Sabre.  The CT Sabre is a robotic arm that fits inside the bore of a micro-CT scanner and is controlled remotely through software, allowing you to perform procedures, such as the delivery of therapeutic agents, biopsies, blood sampling, etc.

Picture
A unit for the eXplore CT120
You can operate the arm during fluoroscopy:
✔ Full control of needle position
✔ Live view of needle under robotic control
✔ Highly accurate needle positioning
✔ Control of animal position
✔ Full control of x-ray angle


Alternatively, you can plan an intervention from a reconstructed 3D volume:
✔ Plan trajectory of needle with full anatomical information
✔ Easy-to-use, interactive planner – point and click to define trajectory
✔ No need to re-position the animal between acquisition and intervention

Picture
Using MicroView to plan the intervention
Safe and effective interventions for:
  ✔ Cardiac perfusion
  ✔ Biopsy
  ✔ Tissue injection
  ✔ Cannulation
  ✔ Blood sampling


If you have any questions or comments about the CT Sabre, we would love to hear from you.  Also, continue to watch this blog for future CT Sabre updates.
Comments

Radiation Treatment with Rapid Fluoroscopy

5/8/2012

Comments

 
Picture
A couple weeks ago, I introduced the Rapid Fluoroscopy application and hinted that it could be used for more than the typical fluoroscopy applications.  In this post, I'm going to elaborate on that.

Parallax Innovations has been working with Dr. Eugene Wong and Ph.D. candidate Michael Jensen at the University of Western Ontario, who have customized their eXplore CT120 to allow it to be used for image-guided radiation delivery.  In particular, they have added a motorized, computer controlled collimator (shown below) to the system that allows them to narrow the x-ray beam for targeting a specific region of the specimen.  The image to the right is of a 4x4 cm radiochromic film showing how they can achieve an elliptical radiation pattern.

Picture
The problem that we helped them solve was how to define a series of exposures at prescribed angles as part of a micro CT protocol.  They needed the ability to fire any number of exposures with any allowable x-ray settings from any gantry position.  And in addition, they needed to be able to control the size of the collimator aperture at any given gantry position.  Except for the control of custom collimator, the requirements seemed to me to be close to the functionality already provided by the Rapid Fluoroscopy application.  Parallax Innovations  assisted by implementing a new custom protocol to the application – the treatment protocol.

Treatment protocols allow the operator to specify any number of gantry angles and for each angle, specify a number of other properties.  As you can see in the property editor pictured below, one can prescribe the x-ray settings (voltage/current/duration), a table offset from the landmark position, the focal spot size, and how many exposures to fire.  There are also settings for the maximum allowable anode heat before the exposures at this particular position can begin (anode heat threshold), the amount of time between exposures (decay time), and an option to wait for a given amount of time before beginning the exposures at this particular position (pause).

Picture
Note: the 140 kV voltage setting is not available with standard x-ray generators.  120 kV is normally the maximum.

For the custom collimator, Michael had already written an application to control it.  I asked him to add a remote procedure call (RPC) interface that would allow the fluoroscopy software to make RPC calls passing the collimator motor positions defined in the treatment protocol.

A custom protocol using Rapid Fluoroscopy was implemented and integrated with collimator control in a timely and efficient manner.  It provided a flexible and simple solution which accelerated the readiness of such a platform for targetted radiation delivery.  Now, when the Rapid Fluoroscopy software is switched on, it is possible to build and run radiation treatment protocols.  Such a combination can also be used for cardiac imaging, with the collimator shielding the rest of the animal from unnecessary radiation exposures, which could potentially improve image quality by reducing scattered radiation.  For more information about Dr. Wong's research, visit the University of Western Ontario website.

Special thanks to Michael Jensen for all the testing he has done with the treatment protocols.
Comments

    Archives

    December 2015
    March 2015
    January 2014
    September 2013
    January 2013
    December 2012
    October 2012
    September 2012
    August 2012
    July 2012
    June 2012
    May 2012
    April 2012
    March 2012
    February 2012
    December 2011
    August 2011
    July 2011
    June 2011
    May 2011
    April 2011

    Categories

    All
    64 Bit
    64-bit
    Cardiac Research
    Contact
    Cornell
    Ct 120
    CT-120
    Ct Reconstruction
    Ct Sabre
    Cuda
    Explore
    Fluoroscopy
    Gizmodo
    Gluster
    Gpu
    Infiniband
    Itk
    Lion
    Locus
    Locus Ultra
    Microct
    Microview
    Mpi
    Nvidia
    Os X
    Preclinical Imaging
    Python
    Radiation Therapy
    Slicer3d
    Sourceforge
    Vtk
    Website
    Welcome
    Wmic

    RSS Feed

Powered by Create your own unique website with customizable templates.